General Specifications

Environmental
Working Temperature 0 to +60ºC
Functional Temperature -25 to +70ºC
Storage Temperature -55 to +85ºC
Temperature Coefficient 0.02% per deg C (100ppm / ºC)
Relative Humidity 95% non-condensing
Class of Climate HSE complying with DIN 40040-3
  complying with VDE/VDI 3540
Insulation
Test Voltage 4kV RMS 50Hz 1min. between Input/Case/
  Auxiliary
Impulse Test EMC 5kV transient complying with IEC801 /
  EN55020
HF Interference Test EHF 2.5kV 1MHz complying with IEC 255-4
Protection Class II complying with IEC 348, BS4753 / DIN
  57411 / VDE 0411
Applied Standards
General IEC 688 / BS6253 / VDE / VDI2192
Safety BSEN61010 DIN 57411 / VDE 04111
Surge Withstand IEC801 / EN55020 ANSI C37-90A
Radio Screening RFI degree N complies with VDE 0875
Accuracy
Class ± 0.2%complying with IEC 688
Calibration temperature 23ºc
Temperature Co-efficient 0.01% / ºC (100 ppm / ºC)
Stability 0.05% per annum non cumalative.
Warm up time < 15 min
Output
Rated Value See individual product pages
Load Resistance mA (Unless otherwise stated) 1mA < 15 kOhm
  5mA < 3 kOhm
  10mA < 1.5 kOhm.
  20mA < 0.75 kOhm
  4-20mA < 0.75 kOhm
Load Resistance Volts (M100-VA1,VA3 only) 1, 5& 10 volts > 50 kOhm
Load Influence < 0.1%
Ripple < 0.5% peak-peak at full load
Response time <200 msec for 0-99 at full load
Overload < 2 x rated value at full load
No load voltage < 27V
Enclosure
Fixing Snap on to DIN rail 35 x 7.5mm complies with DIN-EN 50022 BS 5584
Mounting Any position
Enclosure Code Case IP 50 \ Terminals IP 30 Complies with IEC 529 BS 5490 DIN 40050