Remote Resistance Transducers

Remote resistance Transducer.

Description

DIN rail mounting transducers available in 55mm x 112mm or 100 x 112mm DIN  rail cases

Application

Used to convert various inputs into standard DC signals for driving panel meters and for use in control devices.

Selection Guide
M100-RPM Resistance measurement
Typical Applications

The M100-RPN is designed to measure the resistance of 3 wire potentiometers, where the resistance value is proportional to the position of the wiper of the potentiometer. The output value from the M100-RPN is directly proportional to the resistance value at the wiper. A typical application is monitoring remote resistance of potentiometer used in manual valve control.

Technical Specifications
INPUT  
Rated range min. 100 ohms...max. 50 k Ohms
Sensor current min 20uA...max 10mA
Sensor Voltage 1 Volt
Working Range 0-100% R
OUTPUT  
Rated value mA 1/5/10/20 & 4-20mA
Rated value volts 0-5/10 & 1-5V
ADJUSTMENT  
Zero: 0-35%
Span 65-100%
AUXILIARY  
A.C. Voltage 115/230/400V(±25%/45-65Hz/<2VA)
D.C. Voltage 24/48/110V(±20% /
  galvanically isolated / 3W)
WEIGHT&CASE SIZE  
  Approx 0.4kg. 55mm case
NOTE  
No isolation is provided between input and output
Ordering Information
Product Code Input Output Aux Freq Options
M100-RPN 2kOhm 0-20mA 230V 50Hz  
Options
1 Non standard inputs / outputs only as far as technically acceptable
2 A.C. Auxiliary in range 57.7 to 450 volts
3 Calibration at temperature other than 23ºC